Predispatch¶
30-minute Predispatch (Predispatch)¶
https://www.aemo.com.au/-/media/files/electricity/nem/security_and_reliability/power_system_ops/procedures/so_op_3704-predispatch.pdf?la=en
Runs and is published every 30 minutes
forecasts out to the end of the next market day (4 AM the following day). It can cover a period of up to 48 hours or more.
5-minute Predispatch (P5MIN)¶
Runs and is published every 5 minutes
Forecasts for the next 12 dispatch cycles (one hour)
Extended Predispatch (PD7Day)¶
https://www.aemo.com.au/-/media/Files/Electricity/NEM/Emergency_Management/2017/Guide-to-Extended-Predispatch-Report.pdf
Total demand¶
https://aemo.com.au/-/media/files/electricity/nem/security_and_reliability/dispatch/policy_and_process/demand-terms-in-emms-data-model.pdf?la=en
Table dispatchregionsum:
NetInterchange: negative for import
Gen - NetInterchange(export) = TotalDemand + Load - WDR_Dispatched + AllocatedInterconnectorLosses
Energy reserve¶
Reserve = AvailGen - NetInterchange (Export) - TotalDemand
Table predispatchregionsum, p5min_regionsolution, dispatchregionsum:
TOTALDEMAND: forecast total demand in MW (less normally on loads)AVAILABLEGENERATION: aggregate generation bid available in the region (MW), the sum of all generation units' available capacity.AVAILABLELOAD: aggregate load bid available in the region (MW). This primarily refers todispatchable loadorinterruptible loadthat can be reduced to help balance supply and demand.PREDISPATCHSEQNOformat:yyyymmddxxRUN_DATETIMEformat:yyyy-mm-dd 24hh:mi:ssSETTLEMENT_DATEformat:yyyy-mm-dd 24hh:mi:ss
Regional excess supply¶
https://www.aemo.com.au/-/media/files/electricity/nem/security_and_reliability/power_system_ops/reserve-level-declaration-guidelines.pdf Mainland regions: